top of page

Received a Fire Safety Notice for Your HMO? 5 Common Causes and What to Do Next

6 days ago
6 min read

Written by Dan Luckett, Head of Fire Safety, Orchard Safety. Reviewed for accuracy on 17 October 2026


Receiving a fire safety notice can be unsettling for any HMO landlord. You may be concerned about the work required, possible penalties or the effect on your HMO licence and business.


The first step is to establish what type of notice you have received, which authority issued it and what action is required. From there, you can prioritise the work, gather the right evidence and respond in a structured way.


Here are five common fire safety issues found in HMOs, along with practical steps you can take after receiving a notice.


What is a fire safety notice?


Under the Regulatory Reform (Fire Safety) Order 2005, commonly called the Fire Safety Order, Fire and Rescue Authorities generally enforce fire safety requirements in the common parts of HMOs and other multi-occupied residential buildings.


Local housing authorities also have enforcement powers under the Housing Act 2004 and HMO licensing legislation. The type of notice issued, its legal basis and the action required will therefore depend on which authority has identified the problem.


A notice may require specific improvements to be completed within a stated period. It is important to read the document carefully, note every deadline and identify any information about representations or appeals.


Do not assume that every HMO fire safety notice follows the same process. If any part of the notice is unclear, contact the issuing authority or obtain competent advice as soon as possible.


Why fire safety notices matter


A formal notice means an enforcing authority has identified deficiencies that require action.


These may involve physical features of the building, such as fire doors, alarm systems or escape routes. They may also relate to the way fire safety is assessed, managed and recorded.


Dealing with the findings promptly allows you to protect occupants, organise necessary work and show the enforcing authority that the matter is being managed properly.


1. The Fire Risk Assessment no longer reflects the property


An HMO can change over time. For example:


  • The internal layout may be altered

  • Occupancy levels may increase

  • New facilities may be added

  • Common areas may be reconfigured

  • Rooms or other areas may be used differently


If these changes are not reflected in the Fire Risk Assessment, it may no longer provide an accurate account of the risks within the property.


The assessment should remain suitable and sufficient. It should also be reviewed where there is reason to believe it is no longer valid or after a significant change to the property.


Questions to ask:


  • Does the assessment reflect the current layout?

  • Does it reflect the current occupancy and use of the building?

  • Have its recommendations been completed?

  • Has the property changed since the previous review?

  • Are any rooms or common areas now used differently?

  • Is there clear evidence of when the assessment was reviewed?


A Fire Risk Assessment should reflect the property as it is now, rather than how it looked or operated when the assessment was first completed.


2. Fire door deficiencies


Fire doors are an important part of a property’s fire protection measures. They need to be kept in good condition and work as intended.

Problems identified during an inspection may include:

  • Damage to the door or frame

  • Missing or damaged self-closing devices

  • Excessive gaps between the door and frame

  • Missing or damaged smoke seals

  • Unsuitable alterations

  • Unsuitable replacement doors or components


Unresolved fire door defects may lead to enforcement action where they create an unacceptable level of risk. Having a Fire Risk Assessment does not remove the need to inspect, maintain and repair the doors themselves.


Routine checks can help identify wear, damage or interference before the issue becomes more serious. Records of checks and repairs can also help demonstrate that fire doors are being actively managed.


3. Problems with escape routes


In an emergency, occupants need a clear and protected route out of the building.

Escape routes may be affected by:

  • Items stored in communal corridors

  • Exit doors that require a key to open from the inside

  • Security measures that may prevent evacuation

  • Changes to the building’s layout

  • Damage to fire-resisting walls, ceilings or other construction

  • Faulty emergency lighting

  • Missing emergency-lighting servicing arrangements

  • Poor or unsuitable signage


An issue that appears small during day-to-day use can become significant if it delays or prevents someone from leaving safely.


Communal corridors, stairs and exits should be checked routinely. Any problems found should be recorded and corrected promptly.


4. Inadequate fire detection and warning systems


Installing a fire alarm or detection system is only part of effective fire safety management.

Inspectors may identify:


  • Components that are not working correctly

  • Insufficient coverage for the building’s use, occupancy or risk

  • Missed servicing

  • Incomplete testing records

  • A lack of evidence that defects have been corrected


Landlords should be able to show that the system is inspected, tested and maintained appropriately. Clear records are important because they help show what checks took place, when they were completed and what action followed.


5. Poor management and record keeping


Physical defects are not the only reason an authority may take action. Weak management arrangements can also create compliance concerns.


Examples include:

  • Missing maintenance records

  • Incomplete testing logs

  • Unclear responsibilities

  • No evidence that previous recommendations were completed

  • No documented review process

  • Contractor reports that cannot be located

  • Defects being recorded without evidence of follow-up action


During an inspection, a landlord may need to demonstrate that the property’s fire safety measures are being managed on an ongoing basis. Organised records help show that checks, servicing, repairs and reviews are taking place. Good records should make it clear what was checked, when it was checked, who completed the work and whether any further action was required.


What should you do after receiving a notice?


Start by confirming whether the notice came from a Fire and Rescue Authority or a local housing authority. A notice from a Fire and Rescue Authority may refer to the Fire Safety Order. A local housing authority may act under the Housing Act 2004 or HMO licensing legislation.


Read the notice carefully


Identify:

  • The authority that issued it

  • The legislation referred to

  • Each deficiency listed

  • The work or evidence required

  • The relevant completion dates

  • Any information about representations or appeals

  • The named contact at the issuing authority


Make a clear list of the required actions rather than relying on memory or informal notes.


Clarify anything you do not understand


If a requirement is unclear, contact the issuing authority. Keep a written record of correspondence, clarification received and any agreed actions. Do not make assumptions about what will satisfy the notice, particularly where the requirement involves technical fire precautions.


Prioritise life-safety matters


Give immediate attention to issues that may affect an occupant’s ability to:

  • Receive an effective warning of fire

  • Use the escape route

  • Open an exit door

  • Reach a place of safety

  • Benefit from the building’s fire-resisting construction

The notice itself should guide the work required and the deadlines that apply.


Gather the relevant documents


These may include:

  • The current Fire Risk Assessment

  • Previous versions of the assessment

  • Fire alarm testing and servicing records

  • Emergency-lighting testing and servicing records

  • Fire door inspection records

  • Maintenance certificates

  • Contractor reports

  • HMO licence documents and conditions

  • Photographs of completed work

  • Invoices and completion certificates

  • Correspondence with the enforcing authority


The original draft identifies Fire Risk Assessments, maintenance records, alarm documentation, emergency-lighting records and evidence of completed work as key supporting information.


Keep evidence of the action taken


Record progress from the point the notice is received.

Keep copies of quotations, inspection reports, photographs, emails, invoices and confirmation that remedial work has been completed. If an issue cannot be completed by the stated date, contact the issuing authority rather than allowing the deadline to pass without communication.


Obtain competent advice where appropriate

Some notices involve technical matters that require specialist interpretation. Competent fire safety support can help you understand the findings, identify suitable priorities and organise the evidence needed to show what has been completed.


How can you reduce the risk of future enforcement action?


Fire safety arrangements can fall behind when a property changes or when maintenance and review actions are left incomplete.



Practical steps include:


  • Reviewing the Fire Risk Assessment following relevant changes

  • Completing recommendations within agreed timescales

  • Keeping testing and maintenance records together

  • Checking communal areas routinely

  • Monitoring fire doors and warning systems

  • Recording defects and the action taken

  • Assigning clear responsibility for each task

  • Checking that contractor documents have been received

  • Acting on known issues before the next inspection


The original draft highlights regular reviews, prompt completion of recommendations, organised records and routine checks of communal areas, fire doors and alarm systems.


Simple, consistent arrangements are often easier to maintain than a complicated system that nobody follows.


What may be checked during an HMO fire safety inspection?


The scope of an inspection will depend on the authority involved, the legislation being applied and the circumstances of the property.


Areas reviewed may include:


  • The suitability of the Fire Risk Assessment

  • Means of escape

  • Fire-resisting construction and compartmentation

  • Fire door condition

  • Fire detection and warning systems

  • Emergency lighting

  • Testing and maintenance records

  • Landlord or staff responsibilities

  • Management arrangements

  • Record keeping

  • HMO licence conditions

  • Evidence that earlier recommendations have been completed


These checks may cover both the physical condition of the property and the way its fire safety arrangements are managed.


Have you received a fire safety notice for an HMO?


If you have received a notice from a Fire and Rescue Authority or local housing authority, start by checking who issued it, which legislation is cited and when you need to respond.


We work with HMO landlords and property owners to review fire safety arrangements, understand inspection findings and set clear priorities.


 
 
Orchard Safety Logo - white
  • LinkedIn
  • Facebook
  • Twitter

Lakeview Lodge

Shortheath Road

Moira

Swadlincote

DE12 6BW

Registerd in England and Wales Reg. No: 13501036
VAT Number: 385753944 

©2026 Orchard Safety Ltd

bottom of page